Temperature Range
range 1: –20 °C to 120 °C, range 2: 50 °C to 500 °C (display range: 0 °C to 500 °C)
Housing
industry protection housing IP65, stainless steel, with protection window, air purge and optional water cooling, diameter 110 mm, length 280 mm (without mechanical mounting and connectors), 6 bar max. water pressure, 2 bar max. air pressure
NETD
< 0,06 K (30 °C, 50 Hz, range 1)
Measurement Uncertainty
2 K (object temperature < 100 °C) or 2 % of measured value °C
Measurement Frequency
internal 50 Hz, selectable: 50 Hz, 25 Hz, 12,5 Hz, …
Response time
internal 40 ms , selectable: 2 / measurement frequency
Operating temperature
–10 °C to 50 °C (without water cooling), –25 °C to 150 °C (with water cooling)