Sign In

  • Forgot your password?
  • Need a new account?

Register


DG 55NV

MODEL:DG 55NV

4-6 Weeks Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


DS 56N - Parameter

Weight (g)
750

Operating Temperature (°C)
0 to 70

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.5 % + 1 K

Spectral range (µm)
0.8 to 1.1

Distance ratio
200:1 | 300:1

Reproducibility
0.1 % + 0.5 K

Temperature Range (°C)
–40 to 1000 | 0 to 1000

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

Dimensions
54 mm × 54 mm, length 170 mm

DS 56NV - Parameter

Weight (g)
750

Operating Temperature (°C)
0 to 70

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.5 % + 1 K

Spectral range (µm)
0.8 to 1.1

Distance ratio
200:1 | 300:1

Reproducibility
0.1 % + 0.5 K

Temperature Range (°C)
300 to 1100

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

Dimensions
54 mm × 54 mm, length 170 mm

DG 56N - Parameter

Weight (g)
750

Operating Temperature (°C)
0 to 70

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.5 % + 1 K

Spectral range (µm)
1.5 to 1.8

Distance ratio
200:1 | 300:1

Reproducibility
0.1 % + 0.5 K

Temperature Range (°C)
100 to 1300 | 200 to 1400 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

Dimensions
54 mm × 54 mm, length 170 mm

DG 56NV - Parameter

Weight (g)
750

Operating Temperature (°C)
0 to 70

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.5 % + 1 K

Spectral range (µm)
1.5 to 1.8

Distance ratio
200:1 | 300:1

Reproducibility
0.1 % + 0.5 K

Temperature Range (°C)
300 to 1300 | 400 to 1400 500 to 2500

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

Dimensions

DGE 56N - Parameter

Weight (g)
750

Operating Temperature (°C)
0 to 70

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.5 % + 2 K

Spectral range (µm)
2.0 to 2.6

Distance ratio

Reproducibility
0.3 % + 1 K

Temperature Range (°C)
600 to 1800 | 0 to 2500 | 250 to 1300 | 350 to 1800 | 250 to 2000

NETD (k)
0.5

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

Dimensions
54 mm × 54 mm, length 170 mm

DT 56G - Parameter

Weight (g)
750

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.6 % or 1 K

Spectral range (µm)
5

Distance ratio
75:1 | 100:1

Reproducibility
0.3 % or 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 bis 1800

NETD (k)

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.00

Dimensions
54 mm × 54 mm, length 170 mm

DT 56L - Parameter

Weight (g)
750

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.6 % or 1 K

Spectral range (µm)
8 to 14

Distance ratio
75:1 | 100:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800 | 250 to 2000

NETD (k)

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.200 - 1.000

Dimensions
54 mm × 54 mm, length 170 mm

DSR 56N - Parameter

Weight (g)
750

Operating Temperature (°C)
0 to 70

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.5 % + 1 K

Spectral range (µm)
0.7 to 1.1

Distance ratio

Reproducibility
0.2 % + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 bis 1800

NETD (k)
0.1

Adjustable Response Time
5ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

Dimensions

DSR 56NV - Parameter

Weight (g)
750

Operating Temperature (°C)
0 to 70

Housing
Stainless steel round housing with plug connector, length: approx. 140 mm (without through-lens sighting), ∅ 50 mm

Measurement Uncertainty
0.5 % + 1 K

Spectral range (µm)
0.7 to 1.1

Distance ratio

Reproducibility
0.2 % + 0.5 K

Temperature Range (°C)
–40 to 1000

NETD (k)
0.1

Adjustable Response Time
5ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

Dimensions
54 mm × 54 mm, length 170 mm

DS 55N - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DS 55NV - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
–40 to 1000 | 0 to 1000

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DG 55N - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
1.5 to 1.8

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
50 to 1300 | 100 to 1800 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DG 55NV - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
1.5 to 1.8

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
100 to 1400 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DGE 55N - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 2 K

Spectral range (µm)
2.0 to 2.6

Reproducibility
0.3% + 1 K

Temperature Range (°C)
50 to 1000

NETD (k)
0.5

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DSR 55N - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.7 to 1.1

Reproducibility
0.2% + 0.5 K

Temperature Range (°C)
20 to 850 | 30 to 1000

NETD (k)
0.1

Adjustable Response Time
5ms to 100s

Adjustable Emissivity ε
0.050 - 1.000 (1-channel mode)

DSR 55NV - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.7 to 1.1

Reproducibility
0.2% + 0.5 K

Temperature Range (°C)

NETD (k)
0.1

Adjustable Response Time
5ms to 100s

Adjustable Emissivity ε
0.050 - 1.000 (1-channel mode)

DS 54N - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1

Distance ratio
200:1 | 300:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
–40 to 1000 | 0 to 1000

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DS 54NV - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1

Distance ratio
200:1 | 300:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
300 to 1100

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DG 54N - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
1.5 to 1.8

Distance ratio
200:1 | 300:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
100 to 1300 | 200 to 1400 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DG 54NV - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
1.5 to 1.8

Distance ratio
200:1 | 300:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
300 to 1300 | 400 to 1400 500 to 2500

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DT 54G - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm diameter ∅ 50 mm

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
5

Distance ratio

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
600 to 1800 | 0 to 2500 | 250 to 1300 | 350 to 1800 | 250 to 2000

NETD (k)
< 0.15

Adjustable Response Time

Adjustable Emissivity ε
0.200 - 1.000 via RS-485 interface

DT 54U - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm diameter ∅ 50 mm

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)

Distance ratio

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 bis 1800

NETD (k)
0.1

Adjustable Response Time
2ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DT 54L - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm diameter ∅ 50 mm

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
8 to 14

Distance ratio
75:1 | 100:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800 | 250 to 2000

NETD (k)
< 0.15

Adjustable Response Time

Adjustable Emissivity ε
0.200 - 1.000 via RS-485 interface

DSR 54N - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.7 to 1.1

Reproducibility
0.2% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 bis 1800

NETD (k)
0.1

Adjustable Response Time
5ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DSR 54NV - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm (without through-lens sighting) ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.7 to 1.1

Reproducibility
0.2% + 0.5 K

Temperature Range (°C)
–40 to 1000

NETD (k)
0.1

Adjustable Response Time
5ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DSR 54NF - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm diameter ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.7 to 1.1

Reproducibility
0.2% + 0.5 K

Temperature Range (°C)
100 to 1300 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time
5ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DSR 54NFV - Parameter

Weight (g)
600

Operating Temperature (°C)
0 to 70

Housing
Stainless Steel round housing with plug connector length: 105 mm diameter ∅ 50 mm

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.7 to 1.1

Reproducibility
0.2% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time
5ms to 100s

Adjustable Emissivity ε
0.050 - 1.000

DS 56N - Download

DS 56NV - Download

DG 56N - Download

DG 56NV - Download

DGE 56N - Download

DT 56G - Download

DT 56L - Download

DSR 56N - Download

DSR 56NV - Download

DS 55N - Download

DS 55NV - Download

DG 55N - Download

DG 55NV - Download

DGE 55N - Download

DSR 55N - Download

DSR 55NV - Download

DS 54N - Download

DS 54NV - Download

DG 54N - Download

DG 54NV - Download

DT 54G - Download

DT 54U - Download

DT 54L - Download

DSR 54N - Download

DSR 54NV - Download

DSR 54NF - Download

DSR 54NFV - Download